Your Associate for All Your Regulatory Needs: National & Global Medical Device Regulations
Alpine Quality Consultants takes medical devices and IVDs through CDSCO, EU MDR and IVDR, US FDA, UKCA, SFDA and TGA. One team prepares the licence applications, the technical file and the ISO 13485 quality system, and acts as your in-country representative.

Mandatory Authorization and Registrations for Medical Devices in India under the Medical Devices Rules, 2017 and allied laws
Find your activity in the first column. Blue is the form you apply in, navy is the licence or permission you receive.
Manufacturers
Class A and B: apply to the State Licensing Authority in MD-3 for licence MD-5. Class C and D: apply to CDSCO in MD-7 for licence MD-9.
Importers
The Indian Authorized Agent applies to CDSCO in MD-14 and receives the import licence in MD-15, for every class.
New and investigational devices
Test licence in MD-13 or MD-17, clinical investigation permission in MD-23, and permission for a device with no predicate in MD-27.
| Purpose | Application form | Licence / permission | Authority |
|---|---|---|---|
| Manufacture for sale or distribution, Class A or B | MD-3 | MD-5 | SLA |
| Loan licence to manufacture, Class A or B | MD-4 | MD-6 | SLA |
| Manufacture for sale or distribution, Class C or D | MD-7 | MD-9 | CDSCO |
| Loan licence to manufacture, Class C or D | MD-8 | MD-10 | CDSCO |
| Manufacture for clinical investigation, test, evaluation or training | MD-12 | MD-13 | CDSCO |
| Import licence | MD-14 | MD-15 | CDSCO |
| Import for clinical investigation, test, evaluation or training | MD-16 | MD-17 | CDSCO |
| Import of an investigational device by a government hospital | MD-18 | MD-19 | CDSCO |
| Import of a small quantity for personal use | MD-20 | MD-21 | CDSCO |
| Permission to conduct a clinical investigation | MD-22 | MD-23 | CDSCO + Ethics Committee |
| Clinical performance evaluation of an IVD | MD-24 | MD-25 | CDSCO |
| Import or manufacture of a device with no predicate | MD-26 | MD-27 | CDSCO |
| Import or manufacture of a new IVD | MD-28 | MD-29 | CDSCO |
| Registration of a medical device testing laboratory | MD-39 | MD-40 | CDSCO |
| Registration to sell, stock or distribute (wholesale) | MD-41 | MD-42 | SLA |
Other registrations your device may need
Why Choose AQC?
- Seasoned professionals in medical device and IVD regulatory compliance
- Liaison with notified bodies on QMS matters on your behalf
- Over a decade of success supporting device and IVD companies worldwide
- Commitment to integrity, quality and professionalism
- Experienced technical document writers for quality documents
- Customized solutions and document templates that fit your needs
- Full or as-needed consulting towards certification
- Organizational planning, GAP analysis and project management
- Competitive pricing: a cost-effective route to compliance
- Proven results with our clients

How an engagement runs 5 steps
- Preliminary questionnaireYou tell us the device, intended use, target markets and approvals you hold.
- Classification and roadmapWe classify per market, run a gap analysis and return a regulatory roadmap.
- QMS and technical fileISO 13485 procedures, risk file, clinical evaluation and device master file.
- Submission and liaisonWe file, answer authority and notified body queries and support the audit.
- Post-market supportPMS, PSUR, vigilance, renewals and change notifications.
Global registrations by region
India
CDSCO manufacturing and import licences, BIS, AERB, PC-PNDT, Legal Metrology, GeM and ZED.
India CDSCOAsia Pacific
TGA in Australia; Singapore, Malaysia, Indonesia, Thailand, Vietnam and the Philippines.
ASEANRussia, CIS and Africa
Roszdravnadzor and EAEU; SAHPRA, NAFDAC, PPB and other African authorities.
All marketsQuestions manufacturers ask first
Do I need an Indian Authorized Agent to import medical devices into India?
Yes. A foreign manufacturer cannot apply to CDSCO directly. An authorized agent in India applies for the import licence in Form MD-14 and holds the licence, Form MD-15, on your behalf.
Is ISO 13485 certification required for CE marking under EU MDR?
The MDR requires a quality management system and does not name the standard. In practice EN ISO 13485 is the harmonised route, and notified bodies assess against it.
What is the difference between an EC REP, a UK Responsible Person and a CH-REP?
They are the same role in three jurisdictions. A manufacturer outside the EU, Great Britain or Switzerland must appoint one in each market it sells into. AQC provides all three.
Can one technical file serve several countries?
Largely, yes. A file built to EU MDR Annex II and III covers most of what CDSCO, SFDA, TGA and ASEAN authorities ask for. We add the country-specific forms and declarations.
Not sure which pathway applies to your device?
Send us the device description and the countries you want to sell in. We reply with the classification, the route and a proposal.